General Data
Display: 5 digits ( 0 to 99999 ) LCD display.
Flash adjust Range: 60 to 32,000 RPM/FPM.
* RPM : round per minute.
* FPM : flash per minute.
Resolution: 0.1 RPM :
< 1,000 RPM.
1 RPM :
≧ 1,000 RPM
Function Buttons: Digital rotate knob,
x 2 button, ÷ 2 button,
+ button, - button,
Accuracy:

± (0.05 % + 1d)
Spec. tested under the environment\
RF Field Strength less than 3 V/M &
frequency less than the 30 MHz only.

Power Supply: 110 Vac ± 10%, 50/60 Hz.
or
220 Vac ± 10%, 50/60 Hz.
or
230 Vac ± 10%, 50/60 Hz.
* A " Voltage rating label " is affixed under the bottom case to show the voltage rating of power supply. When use the stroboscope, make sure to identify the power supply voltage exactly.
Circuit: *Microcomputer LSI circuit & crystal control time base. Digital synthesis circuit for the signal adjusting.
Signal Stability: The signal adjusting circuit is used the digital synthesis circuit, the output signal will existing high sta
Power Supply: AC( 100V to 240V ) to DC 9V ( 3A ) adapter, incuded. Build in battery compartment, power can be used the optional DC 1.2 V Ni-MH recharge battery ( UM-1, D size ) x 4 PCs.
Power Consumption: DC 2.4 A ( 3600 FPM )
Operating Temp: 0 to 50 ℃ (32 to 122 ).
Operating Humidity: Less than 80% R.H.
Dimension: 21 x 12 x 12 cm (8.3 x 4.8 x 4.8 inch).
Weight: 1Kg/2.2 LB.
Housing: Compact and impact plastic injection case with plastic mirror type reflector.
Calibration: Crystal time base and microprocessor circuit, don't necessary take any external calibration process.
Accessories Included: Operation manual...........................1 PC. AC( 100V to 240V ) to
DC 9V adapter .....................................................1 PC.
Optional Accessor: Flash Xenon tube....Model : TBXE-2289 DC 1.2 V Ni-MH recharge batteries, UM-1/D size ( BAUM-1) x 4 PCs.
DC 1.2 V Ni-MH batteries charger with AC adapter, complete set.
Model: BACH-110 ( AC 110V power )
Model: BACH-220 ( AC 230V power )
Flash Tube Specificaton
Flash tube: Xenon lamp.
Flash Duration: Approximately 60 to 1,000 microseconds.
Flash color Temp: Xenon white 6,500 K degree.
Flash energy: 4 Watts-seconds (joules).
Beam Angle: 80 degrees.
Flash tube
replacement:
It is required to change the flash tube when the instrument start to flash
irregularly at speeds > 3600 RPM/FPM.
Operating duty
Cycle:
For prolong life and safety, please adhere to the following operation duty
cycle: < 2000 RPM - 2 hours
2001 to 3600 RPM - one hour
3601 to 8000 RPM - 30 minutes
> 8000 RPM - 10 minutes.
* 10 min. cooling off period between cycles.
Download